This document specifies requirements for circular copper alloy flanges and copper alloy collars combined with loose steel plate flanges in PN designations from PN 6 to PN 40 and nominal sizes from DN 10 to DN 1800 in the types shown in Table 1.
This document also specifies dimensions and tolerances, materials and their associated pressure/temperature (p/T) ratings, flange facings and related surface finish, weld repairs, and marking, together with information on bolting, gaskets, application/installation and approximate flange masses.
The flanges specified, with the exception of integral (type 21) flanges, are for attachment to copper or copper alloy tubes in accordance with EN 12449.
NOTE 1 When the flanges specified in this document are required for use with copper or copper alloy tubes to EN 1057 in those tube diameters which are different to EN 12449, this should be agreed between the equipment manufacturer and the flange manufacturer.
NOTE 2 The size of copper and copper alloy tubes is designated by reference to the outside diameter in millimetres.
NOTE 3 See also Annex B.
NOTE 4 Non-gasketed pipe joints are outside the scope of this document.
Table 1 - Types of flanges and collars
[...table not represented...]
When the standard is harmonized under a directive or regulation, the word Harmonized appear. When such an inscription does not appear, it means that the standard is related to / supporting the relevant directive or regulation.
Directive 2014/68/EU of the European Parliament and of the Council of 15 May 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of pressure equipment
Replaces
БДС EN 1092-3:2004
IN DEVELOPMENT
prБДС EN 1092-3:2022
40.60
Close of voting
Mar 3, 2022
Аn opinion on draft and published standards at national, European and international level can be given at stage 40.20 Public Enquiry, 90.20 Systematic review and 95.20 Proposal for withdrawal for pure national standards.
The members of technical committees with active participation have the obligation to vote on drafts at stage 30.20 Committee voting and 50.20 Formal Vote as well.
An opinion on the document can be submitted by clicking on the "Login" button, if you have an account. If you do not have an account, you need to click on the "Login" button, then register by creating your account and return to this draft/standard.