БДС EN ISO 10993-1:2021

Biological evaluation of medical devices — Part 1: Evaluation and testing within a risk management process

Apr 15, 2021

General information

60.60     Apr 15, 2021

BDS

ТК-87

European Standard

11.100.20  

English  

The standard is being translated and is in the "Technical check" state

Buying

Published

Language in which you want to receive the document

Scope

This document specifies:
— the general principles governing the biological evaluation of medical devices within a risk management process;
— the general categorization of medical devices based on the nature and duration of their contact with the body;
— the evaluation of existing relevant data from all sources;
— the identification of gaps in the available data set on the basis of a risk analysis;
— the identification of additional data sets necessary to analyse the biological safety of the medical device;
— the assessment of the biological safety of the medical device.
This document applies to evaluation of materials and medical devices that are expected to have direct or indirect contact with:
— the patient's body during intended use;
— the user's body, if the medical device is intended for protection (e.g., surgical gloves, masks and others).
This document is applicable to biological evaluation of all types of medical devices including active, non-active, implantable and non-implantable medical devices.
This document also gives guidelines for the assessment of biological hazards arising from:
— risks, such as changes to the medical device over time, as a part of the overall biological safety assessment;
— breakage of a medical device or medical device component which exposes body tissue to new or novel materials.
Other parts of ISO 10993 cover specific aspects of biological assessments and related tests. Device-specific or product standards address mechanical testing.
This document excludes hazards related to bacteria, moulds, yeasts, viruses, transmissible spongiform encephalopathy (TSE) agents and other pathogens.

Life cycle

PREVIOUSLY

Replaces
БДС EN ISO 10993-1:2010

NOW

PUBLISHED
БДС EN ISO 10993-1:2021
60.60 Standard published
Apr 15, 2021

Related project

Adopted from EN ISO 10993-1:2020

Adopted from ISO 10993-1:2018

Preview

Only informative sections of projects are publicly available. To be in charge of development of standards, you will need to become a member of the Technical committee. If you are a member, please log in to your account by clicking on the "Log in" button.

Login